The Advanced Acoustics Mel-Acoustic Slab 75mm is a 75mm open-cell melamine acoustic foam panel, measuring 600mm × 1200mm. The panel is 75mm deep, providing broadband absorption from the lower-mid up to the high frequency range. Each panel covers 0.72m². The 75mm depth takes absorption further into the low-mid frequency range than the 25mm and 50mm slabs, which suits rooms where reverberation is a problem across the full speech and music range. The foam is white throughout — the colour is the melamine itself, not a coating — and is classified Class '0' to BS 476 Parts 6 and 7. At 16kg/m³ it remains light and easy to handle, and it cuts to size on site. Available in White. Manufactured in the UK.
Jump to: Applications • Product Benefits • Installation • FAQs • Technical Details
Applications
Control rooms, mixing and mastering rooms — critical listening environments. Accurate monitoring needs a room with consistent, predictable reverberation. The 75mm slab reduces the influence of room reflections on the monitoring position, improving the accuracy of what you hear. Install on the primary reflection points — the side walls, rear wall and ceiling.
Drum rooms, live rooms and rehearsal rooms. Loud, full-range sources build up reverberant energy quickly, making it hard for musicians to hear each other. The deeper foam tames that build-up across a wider part of the frequency range than thinner panels. Distribute panels across the walls rather than concentrating them in one area, so absorption is even across the room.
Film, production and post-production suites. Production and post environments need a controlled, neutral room so that what is monitored reflects the final output. The white finish suits facilities with light interiors where grey or black foam would stand out.
Home cinemas, high-end listening rooms and Class '0' specifications. The 75mm slab suits dedicated cinema and listening rooms where more absorption than a thin panel is wanted. Where the surface lining must meet Class '0', it provides deeper absorption in a compliant finish. Requirements vary by building, so confirm yours with building control or your fire risk assessor. Fire test certificates are available on request.
Product Benefits
75mm depth — deeper absorption. The 75mm foam core absorbs further down the frequency range than the 25mm and 50mm slabs. It is the appropriate specification where the 50mm panel has proved insufficient, or where low-mid reverberation is a significant part of the problem. For the deepest treatment in the range, see the 100mm slab. Foam panels mainly absorb mid and high frequencies, so for boom collecting in the corners, add corner bass traps alongside.
Class '0' fire classification. The foam is classified Class '0' to BS 476 Parts 6 and 7 and also carries B1 to DIN 4102, V-0 and HF-1 to UL94, and EN 13501-1, and fulfils FMVSS 302.
White throughout the foam. The white finish is the natural colour of the melamine, not a surface coating, so there is no painted layer to chip or wear.
16kg/m³ — light to handle and fix. The low density keeps even the 75mm panel easy to carry, position and fix on walls and ceilings, and it can be cut to size on site.
Heat and chemical resistance. Continuous service temperature up to 150°C. Resistant to hydrolysis, alcohols, hydrocarbons, most organic solvents and dilute acids and bases.
CNC cut for consistent dimensions. Every panel is cut to the same 600mm × 1200mm size, so panels sit edge to edge without adjustment.
Specification and compliance. 16kg/m³ melamine foam density. Class '0' to BS 476 Parts 6 and 7; B1 to DIN 4102; V-0 and HF-1 to UL94; EN 13501-1; FMVSS 302. Panel size 600mm × 1200mm × 75mm. 0.72m² coverage per panel. 600g per panel. White. Manufactured in the UK and shipped from stock.
Installation
Installing our acoustic foam panels is very simple. The first step to take is to work out your preferred layout of acoustic panels. Do a sketch on paper first to make sure that the layout looks right and you have enough acoustic foam and space for your planned design.
Once the acoustic panels are mounted to the wall or ceiling they are hard to remove so it is important to get the layout right before you begin. Once you have a sketch of the layout you plan you can then mark up the wall with the layout. You can either use pencil, masking tape or lasers to layout the design on the wall or ceiling.
When mounting the acoustic panels to the wall apply Advanced Acoustics Contact Adhesive to both the back of the panel and the mounting surface. There is no need to heavily cover the acoustic foam or wall with adhesive, a band of adhesive around the perimeter of the tile along with 50% - 75% coverage of the rest of the acoustic panel will be fine. Use the same equivalent amount on the wall. Avoid overspray on the tile and the wall so that adhesive can’t be seen when the panels are in place. Masking Tape on the wall will help with this. If you do get webbing overspray on the foam panel, don’t touch it, allow it to dry, in most cases you will be able to peel the adhesive off.
The adhesive we supply is solvent based so we recommend that you keep all doors of the room and any windows open whilst completing the installation.
If you prefer to have a more temporary installation of acoustic panels you can mount the acoustic foam onto 6mm MDF or ply. These panels can then be hung on the wall using a D-Ring and picture hook for a damage free installation. If fitting them to a ceiling then 4 mirror plates would be required.
Frequently Asked Questions
Which thickness do I need?
Deeper foam absorbs further down the frequency range, so the 75mm reaches further into the lower mids than the 50mm. Choose it where the 50mm has proved insufficient, or in rooms with a loud, full-range source such as drums. If you still need more, the 100mm is the deepest slab in the range. Each step up takes more depth off the room.
My room sounds boomy. Will these panels fix it?
Foam panels mainly absorb mid and high frequencies, which cures echo, flutter and harshness. Boom is low-frequency energy that collects in the corners, and wall panels do little about it. Add corner bass traps for that, or see our Studio Starter Kits, which pair tiles with bass traps.
Can I fix the panels to a ceiling?
Yes. The foam is light, which makes ceiling fixing straightforward. Apply Advanced Acoustics Contact Adhesive to both the panel and the ceiling and press firmly into place, or mount the panel onto 6mm MDF or ply and fix it with four mirror plates if you'd like it to be demountable. Treating the ceiling above the listening or recording position is usually a priority.
How much room will the panels take up?
Each panel is 75mm deep, so panels on two opposite walls take 150mm off the width of the room. In a small room, allow for that before ordering.
What if my room still doesn't sound right after fitting the panels?
All products carry a 30-day money-back guarantee. If the improvement is less than you expected, the cause is usually placement or coverage rather than the product. Contact us with your room dimensions and a photo and we'll advise on layout before you decide whether to return anything. Call 01623 643609 or email info@advancedacoustics-uk.com.
The Technical Details
| Product Name | Mel-Acoustic 75mm Slab Panel 600x1200 |
| Product Size | 600mm x 1200mm |
| Panels Per Box | 1 |
| Area Covered Per Panel | 0.72sqm |
| Product Thickness | 75mm |
| Noise Reduction Coefficient (NRC) | 0.95 |
| Product Colour | White |
| Product Weight | 600g |
| Fire Classification |
DIN 4102 - B1 FMVSS 302 - Fulfilled BS 476, part 6 & 7 - Class 0 UL94 - V-O, HF-1 EN13501-1 |
| Chemical Resistance | Resistant to hydrolysis, alcohols, hydrocarbons, most organic solvents and dilute acids & bases. |
| Foam Density | 16kg/m3 |
| Tensile Strength | 120kPa |
| Hardness | 40% deformation : 7-20kPa |
| Compression Set | 50% at 70øC for 22 hours : 10%-20% |
| Cell Count | 130-200 ppi approx |
| Thermal Conductivity | C0.035W/mK @ 10øC |
| Continuous Service Temperature | 150øC |
| Toxicity | DIN 4102 Class A2 |