The Advanced Acoustics Mel-Acoustic Slab 25mm is a 25mm open-cell melamine acoustic foam panel, measuring 600mm × 1200mm. The panel achieves NRC 0.55 (Sound Absorption Class D), providing effective absorption across the mid and high frequency range. Absorption increases with frequency: 0.18 at 250Hz, 0.410 at 500Hz, 0.69 at 1kHz, 0.84 at 2kHz and 0.87 at 4kHz. Each panel covers 0.72m². The foam is white throughout — the colour is the melamine itself, not a coating — and is classified Class '0' to BS 476 Parts 6 and 7, so it can be used where a white, fire-rated acoustic surface is required. At 16kg/m³ it is very light and easy to handle, and it cuts to size on site. Available in White. Manufactured in the UK.
Jump to: Applications • Product Benefits • Installation • FAQs • Technical Details
Applications
Vocal booths, podcast and broadcast studios — light reverberation control. Small rooms with bare, parallel walls give recordings a tight, boxy sound as reflections stack up around the microphone. The 25mm slab absorbs those mid and high frequency reflections while taking very little room space, which suits booths and small studios where every centimetre counts.
Home cinemas and listening rooms — a light-coloured finish. The panels are white throughout, so they blend into light interiors where grey or black foam would stand out. Place them at the first reflection points on the side walls and across the rear wall to reduce echo and improve clarity.
Offices, meeting rooms and public buildings — Class '0' treatment. Where the surface lining must meet Class '0', as in circulation areas, corridors and other public spaces, the panel provides acoustic absorption in a compliant white finish. Requirements vary by building, so confirm yours with building control or your fire risk assessor. Fire test certificates are available on request.
Custom enclosures and equipment housings — lightweight, heat-resistant lining. Melamine foam withstands continuous temperatures up to 150°C, which suits linings around warm equipment. It absorbs sound inside the enclosure but does not block it. To contain noise, combine it with a barrier, or see the Silent Panel range, which bonds barrier and absorber in one panel.
Product Benefits
NRC 0.55 / Sound Absorption Class D — mid and high frequency absorption in a thin profile. The 25mm foam core controls the high-frequency reflections that cause echo and brightness. It is the thinnest slab in the Mel-Acoustic range and the appropriate specification where space is limited and the problem is echo rather than low-mid build-up. Where lower-mid reverberation is also a problem, the 75mm or 100mm slab is the appropriate step up.
Class '0' fire classification. The foam is classified Class '0' to BS 476 Parts 6 and 7 and also carries B1 to DIN 4102, V-0 and HF-1 to UL94, and EN 13501-1, and fulfils FMVSS 302.
White throughout the foam. The white finish is the natural colour of the melamine, not a surface coating, so there is no painted layer to chip or wear.
16kg/m³ — light to handle and fix. The low density makes the panel easy to carry, position and fix on walls and ceilings, and it can be cut to size on site.
Heat and chemical resistance. Continuous service temperature up to 150°C. Resistant to hydrolysis, alcohols, hydrocarbons, most organic solvents and dilute acids and bases.
CNC cut for consistent dimensions. Every panel is cut to the same 600mm × 1200mm size, so panels sit edge to edge without adjustment.
Specification and compliance. 16kg/m³ melamine foam density. Class '0' to BS 476 Parts 6 and 7; B1 to DIN 4102; V-0 and HF-1 to UL94; EN 13501-1; FMVSS 302. Panel size 600mm × 1200mm × 25mm. 0.72m² coverage per panel. 200g per panel. White. Manufactured in the UK and shipped from stock.
Installation
Installing our acoustic foam panels is very simple. The first step to take is to work out your preferred layout of acoustic panels. Do a sketch on paper first to make sure that the layout looks right and you have enough acoustic foam and space for your planned design.
Once the acoustic panels are mounted to the wall or ceiling they are hard to remove so it is important to get the layout right before you begin. Once you have a sketch of the layout you plan you can then mark up the wall with the layout. You can either use pencil, masking tape or lasers to layout the design on the wall or ceiling.
When mounting the acoustic panels to the wall apply Advanced Acoustics Contact Adhesive to both the back of the panel and the mounting surface. There is no need to heavily cover the acoustic foam or wall with adhesive, a band of adhesive around the perimeter of the tile along with 50% - 75% coverage of the rest of the acoustic panel will be fine. Use the same equivalent amount on the wall. Avoid overspray on the tile and the wall so that adhesive can’t be seen when the panels are in place. Masking Tape on the wall will help with this. If you do get webbing overspray on the foam panel, don’t touch it, allow it to dry, in most cases you will be able to peel the adhesive off.
The adhesive we supply is solvent based so we recommend that you keep all doors of the room and any windows open whilst completing the installation.
If you prefer to have a more temporary installation of acoustic panels you can mount the acoustic foam onto 6mm MDF or ply. These panels can then be hung on the wall using a D-Ring and picture hook for a damage free installation. If fitting them to a ceiling then 4 mirror plates would be required.
Frequently Asked Questions
Which thickness do I need?
The 25mm slab reaches NRC 0.55 (Class D) and the 50mm slab NRC 0.9 (Class B), so the 50mm absorbs considerably more across the range, including the lower mids. The 25mm is the right choice where space is limited and the problem is echo and brightness. If the room also sounds boomy or muddy in the lower mids, the 50mm, 75mm or 100mm slab is the step up.
Do I need bass traps in a vocal booth as well?
Vocal booths tend not to require bass traps, and in most cases acoustic panels are sufficient for this application. Treat the walls behind and beside the microphone first. If the booth is unusually boomy, contact us with its dimensions and we'll advise.
Why choose Mel-Acoustic over standard grey acoustic foam?
Choose Mel-Acoustic when you need the white finish, a Class '0' fire classification, or heat resistance (continuous service up to 150°C). The foam is also much lighter, at 16kg/m³ against 30kg/m³ for our standard polyurethane foam, which makes it easier to carry and fix. If you don't need those, our standard grey acoustic foam is the alternative.
Will the panels stop sound getting in or out of my room?
No. Acoustic foam absorbs sound inside the room, which reduces echo and reverberation. It doesn't block sound passing through walls, floors or ceilings. Stopping noise travelling between spaces needs mass and decoupling, such as Mass Loaded Vinyl and acoustic plasterboard. Sort that first if it's your main problem, then use the panels to improve how the room sounds.
What if my room still doesn't sound right after fitting the panels?
All products carry a 30-day money-back guarantee. If the improvement is less than you expected, the cause is usually placement or coverage rather than the product. Contact us with your room dimensions and a photo and we'll advise on layout before you decide whether to return anything. Call 01623 643609 or email info@advancedacoustics-uk.com.
The Technical Details
| Product Name | Mel-Acoustic 25mm Slab Panel 600x1200 |
| Product Size | 600mm x 1200mm |
| Panels Per Box | 1 |
| Area Covered Per Panel | 0.72sqm |
| Product Thickness | 25mm |
| Noise Reduction Coefficient (NRC) | 0.55 |
| Sound Absorption Class | D |
| Product Colour | White |
| Product Weight | 200g |
| Fire Classification |
DIN 4102 - B1 FMVSS 302 - Fulfilled BS 476, part 6 & 7 - Class 0 UL94 - V-O, HF-1 EN13501-1 |
| Chemical Resistance | Resistant to hydrolysis, alcohols, hydrocarbons, most organic solvents and dilute acids & bases. |
| Foam Density | 16kg/m3 |
| Tensile Strength | 120kPa |
| Hardness | 40% deformation : 7-20kPa |
| Compression Set | 50% at 70øC for 22 hours : 10%-20% |
| Cell Count | 130-200 ppi approx |
| Thermal Conductivity | C0.035W/mK @ 10øC |
| Continuous Service Temperature | 150øC |
| Toxicity | DIN 4102 Class A2 |